Portal
Language
 
Home>Knowledge Base>Understanding the Operating Temperature Range for the ioDrive
Information
Article ID37
Created On10/6/2009
Modified10/6/2009
Share With Others
Understanding the Operating Temperature Range for the ioDrive
Understanding the Operating Temperature Range for the ioDrive

Understanding the Operating Temperature Range for the ioDrive

The ioDrive is designed to operate in an system where the temperature ranges from 0 degrees C to 55 degrees C, with at least 300 LFM airflow*.  This ambient or environmental temperature range is provided in the ioDrive data sheets.  The end user can compare the ambient temperature reading as reported by fio-status with what is listed in the data sheets.  (The 1.2.6 fio-status utility reports "board temperature" in place of  "ambient temperature".)

The product data sheets are available at:
http://www.fusionio.com/Products.aspx

Sample fio-status Output

$ fio-status -a
Fusion-io driver version: 1.2.5
fct0 Attached as 'fioa' (block device)
Fusion-io ioDimm3 320GB Product Number: FS1-001-123-CS SN:1234
ioDimm3, PN:001195011 Mfr:000 Date:20080709
Firmware v24160
322.46 GBytes block device size, 396 GBytes physical device size
4096 blocks, 512 pages, 189056 bytes/page (25 pads, 2 planes, 4 banks) Samsung (ec) SLC
Error correction: 11 bits per 240 bytes, retire above 4 bits
FPGA ID:000 UID:0000000002cf01326845000048f00c00
PCI: 02:00.0, Slot Number: 13 Vendor: 1aed, Device: 1003, Sub vendor:laed, Sub device:1010
Internal temperature: avg 44.3 degC, max 50.7 degC
Ambient temperature: 40 degC
Internal voltage: avg 1.0V, max 1.0V; Aux voltage: avg 2.5V, max 2.5V
Media status: Healthy. 99.78% blocks good. data:99.77% good, md:100.00% good.

* Warning: Operating the ioDrive in an environment outside of the thermal limits specified may shorten the life span of the ioDrive and void its warranty.
   LFM = Linear Feet per Minute.